Post

OpenScan Macro Add-on: Manual

How to install the pre-assembled OpenScan Macro Add-On onto an existing OpenScan Mini & Classic The process is straight-forward and you'll need 10-20mins.

OpenScan Macro Add-on: Manual

OpenScan Mini + Macro

(jump to manual for OpenScan Classic below)

Needed:

  • OpenScan Mini (assembled)
  • OpenScan Macro Add-on
  • Allen Key + screw driver

Step 1: Remove polarizer (green), unplug camera cable (yellow) and ringlight cable (red)

Step 2: unscrew ringlight (red) and camera (yellow)

Step 3: Use two M3x8 screws to mount the Arducam IMX519 onto the Macro module (cable connector facing right)

Step 4: Use four M3x12 screws (red) to mount the lens module in the shown orientation (yellow)

Step 5: Connect camera cables (exposed copper facing away from the camera - yellow) and the ringlight cable (red)

Remove the lens cover by turning it slightly counter-clockwise and you are ready to go :) (No changes in software needed)

OpenScan Classic + Macro

Needed:

  • OpenScan Classic (assembled)
  • OpenScan Macro Add-on
  • Allen Key + screw driver

Step 1: Remove default polarizer (red) and unplug ringlight cable (yellow):

Step 2: Unscrew ringlight (four M3x8 screws):

Step 3: Remove camera cable (yellow) and unscrew camera (red):

Step 4: Use two M3x8 screws to mount the Arducam IMX519 onto the Macro module (cable connector facing right):

Step 5: Reconnect the ringlight and camera cables (exposed copper side of camera cable facing up):

Step 6: Use four M3x12 screws to mount the lens module (camera cable facing down):

Remove the lens cover by turning it slightly counter-clockwise and you are ready to go :) (No changes in software needed)

Printable files and more details

The 3d printable files and the svg describing the polarizer sheet are available at Printables

There will be another blog article covering the individual components of the Macro Add-on in more detail here